Skip to content

Relaxation discrepency with ASE when using small MACE model #582

Description

@akwarii

Description

We are currently implementing and benchmarking TorchSim workflows within atomate2 to enable batching for elastic and phonon properties. While production-grade models (like mace-medium) show excellent agreement between the ASE and TorchSim backends, we have encountered a significant divergence in relaxed structures and elastic constants when using a smaller toy/test MACE model (MACE.model from the atomate2 test suite).

Both backends use the Frechet cell filter and FixSymmetry constaint.

The whole discussion can be found here: materialsproject/atomate2#1505

Currently, I suspect this could be due to subtle differences in:

  1. Internal line-search or backtracking implementations under noisy/spurious force gradients.
  2. The exact coupling of strain and atomic positions during the optimization step within the cell filter.

Any help would be appreciated!

Reproduction Data

System: Silicon primitive cell (Si2)

  • Initial lattice parameter $a$: 3.866975 Å

1. Optimized Lattice Parameters

  • ASE (test model): $a =$ 3.801120 Å
  • TorchSim (test model): $a =$ 3.851698 Å
  • ASE (mace-medium): $a =$ 3.866058 Å
  • TorchSim (mace-medium): $a =$ 3.865821 Å

2. Computed Elastic Constants (GPa)

Backend & Model $C_{11}$ $C_{12}$ $C_{44}$
ASE (mace test) 9.703 9.699 0.002
TorchSim (mace test) 7.650 7.647 0.334
ASE (mace medium) 126.967 65.841 67.297
TorchSim (mace medium) 127.030 65.890 67.330