Aggregation of multiple CAN messages in 1722 frame #20

@adriaan-niess

Description

@adriaan-niess

Based on comment from @JLPLabs we should consider adding support to aggregate multiple CAN frames into a single Ethernet frame.

Adriaan,
You'll see a 3rd commit on this PR.

NOTE PLEASE LET ME KNOW:
a) if this is more than you want,
b) if there is a better / more idiomatic approach I should be taking.

This last change can be summarized as:

  • LISTENER

    • updated one line in acf-can-listener so that the acf_pdu pointer is moved through the ethernet frame. (right now there is logic that seems to imply that was the desired behavior, but the pointer wasn't actually being updated).
  • TALKER

    • added a --count COUNT flag to the command line. This allows the user to require COUNT number of CAN frames to be packed into one Ethernet frame.
    • used the variable that already existed, num_acf_msgs for handling the count logic.

Originally posted by @JLPLabs in #18 (comment)